Chemical Oxygen Demand (COD) Analyzer Sensor

Chemical Oxygen Demand Analyzer Sensor adalah alat untuk melakukan pengukuran oksigen yang dibutuhkan untuk mengoksidasi bahan organik yang larut dan partikulat dalam air.
[wptab name=’Features’]
- Solution Without Cabinet , Robust IP 68 Water Submersible Enclosure
- 1 second Online Real time Measurement
- 0.2 W Ultra Low Power Consumption, Ideal for Out door Applications
- High Reliability and Drift Free
- Lightening, Surge Protection for Power, and RS 485 Communication
- Engineering Cost, 1.2 Km RS 485 Digital Communication, and Minimize Cabling
- Software Configuration Calibration, Data Monitoring
- Standard Modbus RTU Protocol, Direct Connected with PLC, HMI, Eliminate I/O Module Cost
- Auto Cleaning, Almost No Maintenance
- Turbidity or Total Suspended Solids Measurement, Compensation
- Onboard memory allowing users to easily calibrate, configure sensor at lab, and distribute to various fields sites
[/wptab]
[wptab name=’Specification’]
| Measurement range | 1: 0 – 100 mg/L 2: 0 – 800 mg/L 3: 0 – 2,500 mg/L 4: 0 – 5,000 mg/L 5: 0 – 10,000 mg/L |
| Accuracy | ± 5% in standard solution ± 2.5 mg/L |
| Resolution | 0.01 mg/L |
| Repeatability | ± 3% in standard solution ± 2.5 mg/L |
| Light source | LED 254 nm |
| Beam angle | 180° |
| Light path length | 1 mm, 2 mm, 5 mm, 10 mm, 35 mm |
| Process flow rate | Max. 3m/sec |
| Operation pressure | Max.10 Kg f/cm2 |
| Operating temperature | 0 – 85 °C |
| Response time | < 1 min |
| Protection | IP 68 |
| Temperature sensor | Pt 100 |
| Temperature measurement range | 0 – 85 °C |
| Temperature accuracy | ± 0.5 °C; ± 0.1 °C (Optional) |
| Turbidity sensor | LED 880 nm |
| Turbidity measurement range | 1: 0 – 50 NTU (or 0 -100 mg/L) 2: 0 – 500 NTU (or 0 – 1,000 mg/L) 3: 0 – 2,000 NTU (or 0 -5,000 mg/L) 4: 0 – 4,000 NTU (or 0 -10,000 mg/L) 5: 0 – 10,000 NTU (or 0 – 20,000 mg/L) |
| Turbidity accuracy | ± 5% FS |
| Housing | SS 316 L; Titanium |
| Dimension | 40 Χ 240 mm |
| Weight | Analyzer: approx. 1 Kg; Cable: 80 g/m |
[/wptab][end_wptabset]
Butuh Solusi untuk Kebutuhan Anda?
Temukan produk, layanan, dan solusi instrumentasi yang sesuai dengan kebutuhan industri, laboratorium, dan monitoring lingkungan Anda.
Artikel Terkait

Chemical Oxygen Demand (COD) Analyzer Sensor

Chemical Oxygen Demand Analyzer Sensor adalah alat untuk melakukan pengukuran oksigen yang dibutuhkan untuk mengoksidasi bahan organik yang larut dan partikulat dalam air.
[wptab name=’Features’]
- Solution Without Cabinet , Robust IP 68 Water Submersible Enclosure
- 1 second Online Real time Measurement
- 0.2 W Ultra Low Power Consumption, Ideal for Out door Applications
- High Reliability and Drift Free
- Lightening, Surge Protection for Power, and RS 485 Communication
- Engineering Cost, 1.2 Km RS 485 Digital Communication, and Minimize Cabling
- Software Configuration Calibration, Data Monitoring
- Standard Modbus RTU Protocol, Direct Connected with PLC, HMI, Eliminate I/O Module Cost
- Auto Cleaning, Almost No Maintenance
- Turbidity or Total Suspended Solids Measurement, Compensation
- Onboard memory allowing users to easily calibrate, configure sensor at lab, and distribute to various fields sites
[/wptab]
[wptab name=’Specification’]
| Measurement range | 1: 0 – 100 mg/L 2: 0 – 800 mg/L 3: 0 – 2,500 mg/L 4: 0 – 5,000 mg/L 5: 0 – 10,000 mg/L |
| Accuracy | ± 5% in standard solution ± 2.5 mg/L |
| Resolution | 0.01 mg/L |
| Repeatability | ± 3% in standard solution ± 2.5 mg/L |
| Light source | LED 254 nm |
| Beam angle | 180° |
| Light path length | 1 mm, 2 mm, 5 mm, 10 mm, 35 mm |
| Process flow rate | Max. 3m/sec |
| Operation pressure | Max.10 Kg f/cm2 |
| Operating temperature | 0 – 85 °C |
| Response time | < 1 min |
| Protection | IP 68 |
| Temperature sensor | Pt 100 |
| Temperature measurement range | 0 – 85 °C |
| Temperature accuracy | ± 0.5 °C; ± 0.1 °C (Optional) |
| Turbidity sensor | LED 880 nm |
| Turbidity measurement range | 1: 0 – 50 NTU (or 0 -100 mg/L) 2: 0 – 500 NTU (or 0 – 1,000 mg/L) 3: 0 – 2,000 NTU (or 0 -5,000 mg/L) 4: 0 – 4,000 NTU (or 0 -10,000 mg/L) 5: 0 – 10,000 NTU (or 0 – 20,000 mg/L) |
| Turbidity accuracy | ± 5% FS |
| Housing | SS 316 L; Titanium |
| Dimension | 40 Χ 240 mm |
| Weight | Analyzer: approx. 1 Kg; Cable: 80 g/m |
[/wptab][end_wptabset]