Telp. 02273518599 | Wa. 081122333715 | Email. [email protected]
Free Chlorine Analyzer
Features:
- Solution Without Cabinet , Robust IP 68 Water Submersible Enclosure
- 1 sec Online Realtime Measurement
- Ideal for Outdoor Applications , 0.05 W Ultra Low Power Consumption
- Temperature Compensation
- Drift Free , High Reliability , No Moving Parts
- Surge Protection for Power , Lightening , RS 485 Communication
- 1.2 Km RS 485 Digital Communication, Minimize Cabling , Engineering Cost
- Software Configuration Calibration , Data Monitoring
- Standard Mod bus RTU Protocol , Direct Connected with PLC , HMI , Eliminate I/O Module Cost
- Almost No Maintenance , Auto Cleaning
- Almost No Consumable , No Reagent , Membrane
- Not Affected by Pressure Fluctuation 1-15 kg f/cm2
- pH Compensation 5-9
- TDS or ORP , Integration Additional Sensors such as Conductivity
- On board memory allowing users to easily calibrate , Distribute to various fields sites, Configure sensor at lab
Specification:
Type 1 & 2: Free Chlorine Analyzer
Measurement range | 1: 0 – 5 mg/L 2: 0 – 5 mg/L (Including pH compensation) |
Accuracy | 0.01 ppm (0 – 0.5 ppm) ; 0.02 ppm (0.5 – 2 ppm) ; 0.1 ppm (2 – 5 ppm) |
Resolution | 0.01 mg/L |
Repeatability | ± 1% FS |
Temperature compensation | 0 – 85 °C |
Automatic pH compensation | 5 – 9 pH (Type 2) |
First setup time | 4 hours |
Process flow rate | Min. 0.8 l/min |
Auto cleaning | Rotating glass ball |
Electrode material | Platinum (Cathode), Copper (Anode) |
Operating pressure | 0 – 10 Kg f/cm2 |
Operating temperature | 0 – 85 °C |
Response time | 3 secs |
Protection | IP 68 |
Temperature Sensor | Pt 100 |
Temperature measurement range | 0 – 65 °C |
Temperature accuracy | ± 0.5 °C ; ± 0.1 °C (Optional) |
Housing | Acrylic |
pH Sensor | |
Measurement range | 0 – 14 pH |
Accuracy | ± 0.05 pH |
Resolution | 0.01 pH |
Repeatability | ± 1% FS |
Operating pressure | Max. 10 Kgf/cm2 (Optional) |
Operating temperature | 0 – 85 °C |
Process flow rate | 0.1l /min |
Response time | 1 sec |
Dimension | 1: 152(W) x 168(H) x 118(D) mm 2: 215(W) x 300(H) x 155(D) mm |
Weight | 1 analyzer: approc. 300g 2 analyzer: approc. 500g ; cable: 80 g/m |
Type 3, 4, & 5: Free Chlorine Analyzer
Measurement range | 3: 0 – 5 mg/L 4: 0 – 10 mg/L 5: 0 – 20 mg/L |
Accuracy | ± 3 % FS |
Resolution | 0.01 mg/L |
Repeatability | ± 3 % FS |
Operating pressure | Max. 10 Kgf/cm2 |
Operating temperature | -5 – 70 °C |
Process flow rate | 0.1 l /min |
Response time | 1 sec |
Temperature sensor | IP 68 |
Temperature measurement range | -5 – 70 °C |
Temperature accuracy | ± 0.5 °C ; ± 0.1 °C (Optional) |
Protection | Pt 100 |
Process Connection | M 26 x 1.5 |
Sensor Material | Glass, Silver/Silver Chloride (Cathode), Platinum (Anode) |
Housing Material | POM |
Dimension | 40 Χ 360 mm |